Murtagh undertook the dismantling of an oil tank which was 25M in diameter and 16M high and sited within an operational plant. The task was carried out just metres away from a building that continued to process fuel and oil products throughout the dismantling process.
The dismantling of this tank was carried out using cold cutting methods to prepare the tank to be cold cut by using a 25M long reach excavator with a shear attachment.
The entire works were completed without any interruption to the on-site manufacturing and production facilities.
Murtagh has subsequently completed the removal of a tank farm and processing equipment from the same site.